메뉴 바로가기

본문으로 바로가기

Home / Product / Detail page

ADAM™ CellT

Automated Cell Counter for cGMP

ADAM™ CellT is an automated cell counter that is available in cGMP production environment. It has an easy-to-use built-in tablet and complies with 21 CFR part 11. When 21 CFR part 11 mode is activated, data cannot be modified by any user.

KEY FEATURES & BENEFITS
- Less than 25 sec to get results
- Cell therapy quality control

- 21 CFR part 11 compliance

- Stem cell, CAR-T cell, CAR-NK cell, Adipose-derived stem cell

- Accurate cell counting and viability

- Automated image analysis

- 4TB extra storage for data backup and recovery


 
An Accurate Automated Cell Counter for cGMP



Various Applications Cell Counter for cGMP

ADAM™ CellT complies with 21 CFR part 11. When 21 CFR part 11 mode is activated, data cannot be modified by any user.
Every action is recorded in an audit trail including the date, time and specific details of the action.
ADAM™ calibration beads allow quick diagnosis when problems occur, which ensures accuracy of the instrument.
 
- Accurate results for cell counting and viability
- 21 CFR part 11 compliance
- Cell therapy quality control
-Various applications: stem cell/ CAR-T cell/ CAR-NK cell/ Adipose-derived stem cell
 

Viability Measurement
PI-Staining Method

After the samples are stained with fluorescent dye, propidium iodide, which intercalates DNA to stain the nucleus of target cells,
ADAM™ CellT takes fluorescent images automatically.
The obtained images are processed by image analysis software integrated inside the system 

 

Data Management
21 CFR Part 11 Compliance

ADAM™ CellT complies 21 CFR part 11 which is a regulation about electronic records and signatures for use in cGMP facilities.
When 21 CFR Part 11 mode is activated, data cannot be modified by any user.
Every action of users is recorded in an audit trail which includes the date, time, and specific details of the action. Electronic signatures based upon biometrics are designed to ensure that they cannot be reused by, or assigned to, anyone else.


 

User Management
Access level and rights of users

 21 CFR Part 11 consists of limiting system access to authorized individuals.
 Users are able to control access within software. It is designated to separate 3 different groups - Admin, Supervisor and User.
 
 

All steps of producing CAR-T cell
QC Platform for producing CAR-T cell

 It is easy to monitor all different steps of the purification, expansion, and formulation of CAR-T cells using the ADAM™ to ensure precise and reliable results. It can be used for cGMP, process control and quality control of CAR-T cell.



 

Data Analysis
Performance Test from Isolated T cells


 
Figure 1 indicates the profiles of T cells that was used for performance evaluation. Flow cytometric analysis of CD3 expression on unsorted or sorted human peripheral blood lymphocytes. Figure 2 indicates linearity showing comparison between flow cytometry and ADAM in Isolated T cells.


Figure 1 shows accuracy of ADAM™-CellT which is a a correlation of Tcell-counting between flow cytometry and ADAM in Isolated T cells. Figure 2 shows repeatability when the concentration of of isolated T cells is low, medium and high.

                                                                                                                                                            









Data Analysis
Performance Test from Activated T cells


The below Image indicates the phenotypes of activated T cells which was used for performancce evaluation.- Flow cytometric analysis of CD25 expression on TCR stimulated or unstimulated T cells.




Figure 1은  shows the comparison of viability between flow cytometry and ADAM™ CellT in Activated T cells. Figure 2 shows repeatability when the concentration of of isolated T cells is low, medium and high

 
 

   
 
Accuracy of system
Validation of ADAM™-CellT

ADAM™ calibration beads allow quick diagnosis when problems occur, which ensures accuracy of the instrument.
Installation Qualification (IQ), Operational Qualification (OQ) and Performance Qualification (PQ) are designed to validate performance of the instrument.

Reference Paper of using ADAM™-CellT 

  

Single-Cell Analyses Identify Brain Mural Cells Expressing CD19 as Potential Off-Tumor Targets for CAR-T Immunotherapies, Cell, 183 (1), pp. 126-142.e17, October, 01, 2020.

Abstract CD19-directed immunotherapies are clinically effective for treating B cell malignancies but also cause a high incidence of neurotoxicity. A subset of patients treated with chimeric antigen receptor (CAR) T cells or bispecific T cell engager (BiTE) antibodies display severe neurotoxicity, including fatal cerebral edema associated with T cell infiltration into the brain. 

 


Expression of the transcription factor PU.1 induces the generation of microglia-like cells in human cortical organoids, Nature Communications13, 430 (2022)


​Link: https://doi.org/10.1038/s41467-022-28043-y

 


Heterozygous frameshift variants in HNRNPA2B1 cause early-onset oculopharyngeal muscular dystrophy, Nature Communications, 13, 2306 (2022)


Link: https://doi.org/10.1038/s41467-022-30015-1

  


A Fully-Human Antibody Specifically Targeting a Membrane-Bound Fragment of CADM1 Potentiates the T Cell-Mediated Death of Human Small-Cell Lung Cancer Cells, International Journal of Molecular Sciences​, 23.13 (2022)


Link: https://doi.org/10.3390/ijms23136895 

  


Generation and Next-Generation Sequencing-Based Characterization of a Large Human Combinatorial Antibody Library, International Journal of Molecular Sciences, 2023


Link: https://doi.org/10.3390/ijms24066011

Mechanisms of reactivation of latent tuberculosis infection due to SIV  coinfection – TB DIAH


A murine model of hnRNPH2-related neurodevelopmental disorder reveals a mechanism for genetic compensation by Hnrnph1. Journal of Clinical Investigation, 2023


(Preprint@bioRxiv: https://doi.org/10.1101/2022.03.17.484791)

 


 A novel bispecific antibody dual-targeting approach for enhanced neutralization against fast-evolving SARS-CoV-2 variants. Frontiers in Immunology, 2023


Link: https://doi.org/10.3389/fimmu.2023.1271508

  


Identification of small molecule inhibitors of G3BP-driven stress granule formation. Journal of Cell Biology, 2024


Link: https://doi.org/10.1083/jcb.202308083

  


Empowering SARS-CoV-2 variant neutralization with a bifunctional antibody engineered with tandem heptad repeat 2 peptide. Journal of Medical Virology, 2024


Link: https://doi.org/10.1002/jmv.29506

  


A dual-targeting approach using a human bispecific antibody against the receptor-binding domain of the Middle East Respiratory Syndrome Coronavirus. Virus Research, 2024


Link: https://doi.org/10.1016/j.virusres.2024.199383

 

Development of a novel CD3ε-specific human antibody for selective modulation of T cell activation. International Journal of Biological Macromolecules, 2025


Link: https://doi.org/10.1016/j.ijbiomac.2025.145859 

 


NanoEntek blog is now open!

Want to learn more about cell counting and cell therapy?

Visit to find out more!

blog-nanoentek.com


FOR RESEARCH USE ONLY.
This product is not approved for diagnostic or therapeutic use.

 

  • Product name / Cat. No.

    ADAM™ CellT / ADAM™ CellT

  • Loading Volume

    13 µL/test (4 ch)

  • Measuring Volume

    3.4 µL/test (4ch)

  • Measuring range

    5 X 10E4–4 X 10E6 cells/mL (PI)
    5 X 10E4–2 X 10E7 cells/mL (AO/PI)

  • Focus

    Auto-focusing

  • LED

    4W Green LED

  • Weight

    7.0 Kg

  • Size

    277 X 276 X 270 mm

  • Analysis time

    < 25 sec/test (4 ch)

  • Dyes

    PI (Propidium Iodide)

  • Connectivity

    WiFi (USB Dongle)

  • Cell type

    Cell line (clumpy cell, single cell), PMBCs, Adipose Stem cell, Total white blood cell, Primary cells

  • Extra storage for data backup and recovery

    4TB

  • LS PRODUCT / ADAM™ CellT

    Bead calibration results are out of range.

    1. Please try vortexing of the bead for a minute, or shake the bead bottle.2. Use bead from the new bead bottle.
  • LS PRODUCT / ADAM™ CellT

    I see a good number of debris in the images taken.

    1. Check if there are no scratches outside or no debris inside the r-Slide.2. If you still see debris when using a new control sample, the control sample may be defective. Please contact your control sample manufacturer.

ExTransfection™ Protocol Library

ExTransfection™ provides open protocols that make it easy for users to set up and run experiments. Its 24-well optimization method helps users to optimize transfection protocols easily and quickly.

ExTransfection™ also offers a pre-programmed optimization protocol that helps an easy and quick optimization of electrical parameters for both adherent and suspended cells.